A Brief History of the EXIT Sign

They are everywhere! “EXIT Signs” are so ubiquitous that most people rarely ever pay attention to them. Even so, all public buildings (restaurants, offices, and even large residential buildings like hotels or multi-unit condos) are required to have emergency lighting and exit signage to clearly illuminate egress locations and provide well-lit, easy to follow direction to them. In the event of an emergency, when every second counts, they provide a potentially life-saving path to quickly get out of the building.

Yet these signs did not exist a little over 100 years ago. It took a deadly industrial accident, one of the worst in American history, to bring about the changes to code and regulations resulting in the EXIT sign.

On March 25, 1911 a fire burst out in the Triangle Shirtwaist Factory, located on the 8th, 9th, and 10th floors of the Asch building in the Greenwich Village neighborhood of New York City. This event would go down in history as one of the deadliest fires ever, with 146 garment workers losing their lives. 

Many of those who died fell or leapt to their deaths, being unable to get out of the burning areas of the building. It turned out that the stairwell doors had been padlocked, a common practice of the times, to discourage employees from stealing product or leaving early.

The resulting media coverage and public outcry led to the establishment of new fire safety regulations including new standards regarding building egress.

Following the recommendations of the state commission, the National Fire Protection Association (NFPA) ratified codes for the first Exit signs. The NFPA had been founded in 1895 by a coalition of Insurance companies. Their purpose was to establish a standardized set of guidelines to help reduce and hopefully eliminate death, injury and economic loss caused by fire. The NFPA guidelines and codes were codified into the basic building codes and standards used throughout the US today. Similar regulations are also used throughout the world.

The Exit Light Company has compiled some useful history and data behind the various codes and regulations. [ https://www.exitlightco.com/Fire-Codes-Regulations.html ]

So the next time you are in a public building, take a minute to look around and make note of the exit signs. Remember, they are there for your safety.

About Certification Marks

You see them on every piece of electronics you buy — whether for personal use, business, or work. But what does that stamped UL, ETL, or CSA indicate? These are Certification Marks, and they provide assurance that you can rely on a standard of safety and performance from the products. All products sold in the United States must pass through a battery of tests performed by a Nationally Recognized Testing Laboratory (NRTL) to prove that the product meets or exceeds national safety standards. Products that pass this inspection and testing process carry the Certification Mark for the laboratory that provided the testing (UL for Underwriter’s Laboratories, ETL for Intertek Testing Services, and CSA for Canadian Standards Association). It doesn’t matter which mark the product carries, as long as it is from one of the organizations that are recognized by the Occupational Safety & Health Administration (OSHA).

 

You can be assured that all products which carry an OSHA recognized NRTL mark will comply with the various safety codes (buidling codes, electrical safety codes, municipal codes and fire codes), has been thoroughly tested by third party laboratories to strict specifications, and complies with all current standards.

 

All emergency lighting and exit signs sold by The Exit Light Company carry Certification Marks. Please see our FAQs to learn more about Certification Marks and NRTLs.

Surviving a Nightclub Fire

As the recent tragedy at the Kiss Nightclub in Santa Maria, Brazil demonstrates, public fire safety continues to remain a serious problem. Any time you mix large crowds of semi-intoxicated people with low levels of lighting, minimal exits, and add smoke and fire, the result is always tragic.

 

In North America there have been several notable nightclub fires:

*Learn more about historical fires in the United States in our State by State Fire FAQs.

After fire analysis has repeatedly noted the importance of well-lit and uncluttered exit pathways, and show that the majority of deaths are usually due to smoke inhalation or trampling. Victims could have survived if they had been able to quickly and safely exit the structure.

 

The Exit Light Company reminds everyone that the sole purpose for the products that we sell (exit signs and emergency lights) is to save lives, not property. Here are some helpful tips for both patrons and business owners:

 

If you are a Patron:

  • Use common sense, don’t patronize businesses in buildings that do not look safe. Some warning signs are that the building does not have a sprinkler system, exit signs or emergency lights are broken and non-functional, or if you see that most of the exit doors are blocked or even locked (chained shut)
  • Be aware of the location of at least two exits at all times (the first being the one that you entered through)
  • Never drink so much that you will not be able to react to an emergency situation
  • If you are caught up in a crowd, it doesn’t matter if you are large and strong, try to get to a wall or to the edge of the crowd. Many deaths are dues to trample injuries
  • Try to stay low, to minimize smoke inhalation
  • If possible, cover your nose and mouth with a cloth. Use your shirt, jacket, or a napkin, if available. If you can, wet the cloth with water. Never use alcohol to wet the cloth, as alcohol is highly flammable
  • Don’t worry about your stuff (purse, backpack, etc.). It’s replaceable, you’re not
  • If you are in a group, agree on an assembly point, somewhere you can all get to safely, then don’t worry too much about keeping together
  • Move safely, and try not to trample/push others, but leave as quickly as possible
  • Stay as calm as possible, and do not give in to panic. This is easier said than done, but panicking will not help you survive

If you are a Business Owner/Facilities Manager:

  • Keep exits and exit paths clear of clutter
  • ALL doors should open outwards so that the crush of a crowd can not pin the doors closed
  • Install and maintain exit signs and exit pathway markings so that the direction of egress is readily apparent
  • Install and maintain emergency lighting so that in the event of loss of power, there will be visibility
  • Keep all emergency equipment (including exit doors) in good working order and test them regularly

*Find out more about maintenance & testing in our helpful FAQs.

Unfortunately, the Kiss Nightclub Fire will not be the last club fire, but if we all keep in mind the above safety tips, we can make sure that we do not contribute to another tragic event or do not end up as another sad statistic.

How to Buy an Exit Sign

Confused? We’ve Got You Covered!

 

Our customers’ needs come in all shapes and sizes. Some are replacing an old exit sign, some are putting up fire exit signs where none existed before and some still haven’t finished construction on the building! No matter what situation brought you here, it can be overwhelming to sort through the selection of exit signs available.

 

First things first: Have you consulted your local building inspector or fire marshal? Even if you’ve never been inspected before, conforming with local building and fire codes is mandatory. Therefore understanding local building and fire codes will prove to be invaluable. Check out our Fire Exit Codes & Regulations section. Consider the following questions:

 

Are there any color or materials requirements my exit signs have to meet?

Certain locales require that exit signs have red lettering, others require green lettering, others allow either but may require consistency within a facility (all green or all red). Some locales require that exit signs be enclosed in steel enclosures, other allow fire-retardant plastic, etc. The City of Chicago require steel exit signs with a glass face. The New York City requires that exit signs have 8” red lettering and be enclosed in durable steel housing. Make sure you are not subject to some of these very limiting requirements.

How many and/or in what areas are exit signs required?

General requirements state that any exit be marked accordingly, but some codes require marking of the “route” to get to the exit as well.

Is there a particular certification my signs need to carry?

The most widely used certification agency in the United States is Underwriters Laboratories Inc. (UL), but some areas require ETL SEMKO certification or other certifications that are more specific. Canada requires a certification from the Canadian Standards Association (CSA).

Are there certain types of units that are prohibited?

Some codes require that your units be hardwired (eliminating power-free choices) or a certain color/material (see question 1).

Once you have gathered the above information from your local authority, it is time for you to make some decisions of your own:

 

Do I have a particular look in mind?

Your local codes may not require it, but perhaps a brushed cast-aluminum sign with lettering fits best with your décor. Maybe you’ve seen an edge lit sign in your favorite store and liked the look, it’s up to you!

Do I have size constraints and/or how do I plan to mount my units?

This question alone may limit your selection to only a few items. Remember that certain mounting configurations may require the use of a mounting canopy that adds 1-2” to the height or width of your sign.
 
This question also encompasses limitations such as a sheet rock, drop or low ceiling.

Will these units be subject to abuse or hazardous environments?

In areas such as schools, gyms, warehouses and parking structures, exits signs may be subject to vandalism, damage from sports equipment and other types of situations which would limit your selection to heavy duty construction or protection such as a wire guard.
 
If installing in areas where the units will be exposed to chemicals, abrasive substances or other hazardous materials, your selection should be limited to units “rated” or qualified for installation in these environments.

By now you will have gathered enough information to narrow your choices to maybe even just one unit! If you are having trouble navigating our site – feel free to contact one of our award winning customer service professionals via phone, email or live chat with your requirements and we will be happy to assist you.

Fire Exit Signs to meet to Federal, State and Local fire codes

Fire Exit Signs, commonly known as exit signs, aid in the emergency egress of building occupants during a fire by providing a lighted version of the word EXIT. Federal, state and local building codes require fire exit signs in all public and commercial facilities. These building codes stipulate the installation locations and placement for fire exit signs throughout the building and the type of fire exit sign that must be installed.

 

While all fire exit signs are required to be illuminated, not all models require electricity. UL 924 listed fire exit signs are available in AC powered, non-electric self luminous Tritium or photoluminescent models all of which are compliant for use in the United States and Canada.

What is the real purpose behind lighted LED exit signs?

Power outages occur in businesses, educational and medical facilities across the country every day. Are you prepared for such an emergency? Many people think that the sole purpose of an exit sign is to mark stairwells and building exits. However, that is only a secondary purpose for lighted LED exit signs.

 

Image of lighted red LED exit signThe real function of lighted LED exit signs is to allow you to find the exit or emergency egress route in the event of an emergency situation. Many times a power outage can be the result of a fire in the building. In such cases, finding the emergency exits can be complicated not only by a loss of power but from the presence of smoke in emergency egress routes. Under these circumstances, lighted exits signs powered by rechargeable backup batteries can literally save lives by allowing individuals to safely exit the building.

 

Most relevant codes (fire, building, health or safety) require exit signs to be permanently lit. The use of light-emitting diode (LED) technology provides brighter illumination than incandescent lamps, resulting in better visibility in a fire situation. LED exit signs also consume much less energy than traditional incandescent models, typically requiring about 4 watts of power to operate. This results in significant cost savings over the life span of the fixture, especially considering that LEDs have a very long life and may last for 10 or more years of continuous use.