Commercial Lighting | Linear High Bay (Standard Output) - Linear High Bay
Base Code: ES-LHB-B1-H1-WH

Key Features
- Field-selectable wattage (70/90/105W)
- Selectable CCT (3500K/4000K/5000K)
- Selectable beam distributions: 45° x 100°, 65° x 95°, or 90° x 90°
- High efficacy up to 164 lm/W
- Emergency driver compatible
- Sensor Ready
- No UV/IR output
Safety Codes and Compliance
- UL/cUL listed
- DLC Premium listed
- Damp location rated
- IP20 rated
- Backed by a 5-Year warranty
Mounting Options
- Pendant mount
- Surface mount
- Hook mount
Built for the aisle, not just the room.
Overview
The Essential Series Linear High Bay combines field-selectable wattage, CCT, and beam distribution in a versatile, high-performance LED fixture. Designed for warehouses, manufacturing facilities, retail spaces, and other open commercial environments, it delivers exceptional efficiency, flexible lighting control, and long-lasting reliability.Dimensions
| Weight | 1.00 lb |
Warranty
Backed by a 5-year limited warranty.
Catalog Ordering Information
| Catalog Number | Size | Wattage Selectable | Lumens Selectable (@40K, 90°x90° Beam Angle) | CCT Selectable | Voltage | Finish |
|---|---|---|---|---|---|---|
| ES-LHB-B1-H1-WH | Standard Output | 70/90/105W | 10360/13320/15540 lm | 35/40/50K | 120-277V | White |
Construction
Durable aluminum and steel housing with a white finish and plastic optical lens. The fixture features a low-glare optical design for improved visual comfort and is rated for use in damp locations.
Illumination
The Essential Series Linear High Bay features field-selectable wattage, three selectable color temperatures, and three selectable beam distributions. Its high-efficiency LED system delivers up to 164 lumens per watt with a CRI greater than 80.
Emergency Operation
Optional emergency drivers are available to provide backup illumination during a power failure. The correct emergency driver must be selected according to the fixture’s output model and installed in the field.
- EB-09-YH36A300 Emergency Driver
Emergency driver unit only; field installation is required.
Operational Temperature
Electrical
Designed for 120-277V, 50/60Hz electrical systems. The fixture supports smooth 0-10V dimming and features a power factor of at least 0.9, maximum THD of 20%, driver efficiency of at least 92%, and 6kV surge protection.
Electrical Specifications
Performance
Total Luminaire Lumens: 10,360 / 13,320 / 15,540 lm
Emergency Lighting Spacing Diagram
Emergency Lighting Spacing Suggestions
45° Beam Distribution
| Egress Path Width | 16 ft | 20 ft | 24 ft |
|---|---|---|---|
| 3 ft | 60 ft | 68 ft | 59 ft |
| 3.5 ft | 61 ft | 69 ft | 60 ft |
| 6 ft | 64 ft | 72 ft | 61 ft |
65° Beam Distribution
| Egress Path Width | 16 ft | 20 ft | 24 ft |
|---|---|---|---|
| 3 ft | 57 ft | 65 ft | 55 ft |
| 3.5 ft | 59 ft | 66 ft | 56 ft |
| 6 ft | 62 ft | 68 ft | 58 ft |
90° Beam Distribution
| Egress Path Width | 16 ft | 20 ft | 24 ft |
|---|---|---|---|
| 3 ft | 52 ft | 52 ft | 43 ft |
| 3.5 ft | 53 ft | 53 ft | 44 ft |